Gas Filters

Coalescing Filters

FilterFab C-Series Filters Remove Liquid Droplets, Liquid Slugs and Dry Particles from Natural Gas Lines

Many gas lines have oil and water in mist or droplet form that, along with solid contaminants such as pipe scale, dirt, and rust, will damage or even destroy your downstream equipment. Use a Filterfab C-Series Coalescing Filter, and you will remove all forms of moisture and dry contamination, lengthening the life of your equipment and saving thousands of dollars in maintenance costs.C-Series Dry Filters have:

  • 4 different closure styles. FilterFab has designed its lid closures to make filter element changeout as easy and as fast as possible. 2" thru 6" line sizes in 180 and 285 psi ratings use a quick-opening swing-bolt lid or blind flange, while larger and higher pressure filters incorporate a blind flange with lifting lug or a lifting davit. Optional threaded high-pressure closures are also available.
  • 4 pressures (MAOP). Available in 180, 285, 740 and 1480 psi.
  • 7 common line sizes. Choose from 2" to 12". Custom sizes to 24" available.
  • A wide range of flowrates. 18,000 to 17,000,000 scfh.
  • Proprietary Coalescing Filter Cartridge. FilterFab's C-Series coalescing filters use a proprietary reverse-flow, radially-finned, high surface area filter cartridge unlike those used by any of our competitors. These cartridges are built with layers of borosilicate fiberglass sandwiched into layers of felted polyester media to remove 99.9% of all liquid droplets, fogs, and mists, plus all particulate matter down to 0.3-microns in size.

Call FilterFab's Sales Department for pricing and a representative in your area. Many model sizes are kept in stock for quick delivery. FILTERS ALWAYS PAY FOR THEMSELVES.

Build a FilterFab C-Series Part Number

To choose the correct FilterFab model for your application, start by building a part number. You will need to know line size and pressure rating. See this example:

To choose the correct FilterFab model for your application, start by building a part number. You will need to know line size and pressure rating. See this example:

C-Series Filter Flowrate Information

Now check the model number you have determined above against the flowchart below to make sure that your choice will handle the flowrate of your application.

FLOWRATE in SCFH for C-Series Filters
Model Number Line Pressure (in psi)
1/4 5 25 50 100 150 250 500 750 1000 1200 1400
C2 17900 20000 38700 48000 65300 79800 175M 240M 295M 400M 465M 546M
C3 33000 42900 85000 98000 150M 182M 400M 575M 665M 850M 990M 1.1MM
C4 58000 85000 147M 155M 266M 330M 680M 920M 1.4MM 1.8MM 2.1MM 2.3MM
C6 168M

190M

350M 390M 637M

770M

1.4MM 1.9MM 2.2MM 2.8MM 3.5MM 3.9MM
C8 280M 345M 540M 700M 1.1MM 1.4MM 2.5MM 3.5MM 4.2MM 5.6MM 7.0MM 7.7MM
C10 385M 636M 770M 1.3MM 1.8MM 2.1MM 4.2MM 5.3MM 6.3MM 8.4MM 9.8MM 12MM
C12 600M 840M 1.5MM 1.8MM 2.8MM 3.4MM 6.2MM 7.7MM 9.8MM 12MM 15MM 17MM

These flowrates are based on 1-1/2 psi pressure drop up to 150 psi; 3 psi for higher line pressures.

Choose a Style

Now look at the styles below the flowrate chart to see the standard body and closure style of your filter. Choose whether to print a hard copy in either Adobe .pdf or AutoCAD .dwg format. To download a .pdf or dwg file, right-click on a link and select "Save Target As..."

STYLE 1 – Quick-Opening Closure
PSI Line
Size
Model Number
Dimensions
Filter Element Downloads
A B C F pdf
180
2"
C2-180F
40"
12"
18"
17"
422
.pdf
180
3"
C3-180F
50"
15"
21"
18"
425
.pdf
180
4"
C4-180F
60"
18"
29"
20"
415
.pdf
180
6"
C6-180F
61"
20"
28"
24"
2035K907
.pdf
285
2"
C2-285F
40"
12"
18"
17"
422
.pdf
285
3"
C3-285F
50"
15"
21"
18"
425
.pdf
285
4"
C4-285F
60"
18"
29"
20"
415
.pdf
285
6"
C6-285F
61"
20"
28"
24"
2035K907
.pdf
ABF diagram
Use this illustration for dimension
measurements in the charts.
STYLE 2 — Blind Flange with Lifting Lug
PSI Line
Size
Model Number
Dimensions
Filter Element Downloads
A B C F PDF
285
8"
C8-285F
65"
18"
33"
28"
2054K907
.pdf
740
2"
C2-740F
40"
12"
18"
17"
422
.pdf
740
3"
C3-740F
50"
15"
21"
18"
425
.pdf
740
4"
C4-740F
60"
18"
29"
20"
415
.pdf
1480
2"
C2-1480F
41"
12"
18"
17"
422
.pdf
1480
3"
C3-1480F
51"
15"
21"
18"
425
.pdf
1480
4"
C4-1480F
61"
18"
29"
20"
415
.pdf
ABF diagram
Use this illustration for dimension
measurements in the charts.
STYLE 3 — Blind Flange with Lifting Davit
PSI Line
Size
Model Number
Dimensions
Filter Element Downloads
A B C F PDF
285
10"
C10-285F
86"
24"
46"
32"
(2)2070K907
.pdf
285
12"
C12-285F
96"
24"
48"
40"
(2)2083K907
.pdf
740
6"
C6-740F
62"
20"
28"
24"
2035K907
.pdf
740
8"
C8-740F
72"
18"
33"
28"
2054K907
.pdf
740
10"
C10-740F
87"
24"
46"
32"
(2)2070K907
.pdf
740
12"
C12-740F
96"
24"
48"
40"
(2)2083K907
.pdf
1480
6"
C6-1480F
62"
20"
28"
24"
2035K907
.pdf
1480
8"
C8-1480F
72"
18"
33"
28"
2054K907
.pdf
ABF diagram
Use this illustration for dimension
measurements in the charts.
STYLE 4 — Blind Flange with Hydraulic Davit
PSI Line
Size
Model Number
Dimensions
Filter Element Downloads
A B C F PDF
1480
10"
C10-1480F
87"
24"
46"
32"
(2)2070K907
.pdf
1480
12"
C12-1480F
97"
24"
48"
40"
(2)2083K907
.pdf
ABF diagram
Use this illustration for dimension
measurements in the charts.